Variable
Note:
1. The following ISO special functions are not supported:
2. If a previously unknown tag cannot be identified based on the parameters above, an error
3. Invalid parameters are rejected with an error message (error_MOBY "15"[hex]).
4. By selecting the values 03 to 07, chip-specific commands are used if they exist. The commands
MOBY U:
Time for BERO mode (field_ON_control = 02)
01 hex ... FF hex
MOBY D:
Transponder type
counter_customer:
Setting for S7 cycles per command execution. Default value is 02.
00 hex
01 hex
02 hex
Note:
If an optimum short cycle time is required on the PLC, "counter_customer" must be set to "0". Larger
values can lengthen the cycle time in the PLC.
The permissible values of the INPUT parameters are listed in the hardware specifications.
FB 45 for MOBY U, MOBY D, RF200, RF300
Function Manual, 07/2012, J31069-D0166-U001-A4-7618
AFI (Application Family Identifier)
DSFID (Data Storage Format Identifier)
Chip-specific added functions such as EAS, Kill commands, etc.
message is generated (error_MOBY "0D"[hex]).
have a positive effect on the communication time between the reader and tag and can therefore
also allow faster data transfer depending on the tag.
00 hex
=
Timeout monitoring is deactivated. The 2nd BERO is needed in order to
switch the field off.
=
1 ... 255s turn on time for the write/read device field.
Binary value:
=
Transponder type
0 ... 255
00 hex
=
I-Code 1 (e.g. MDS D139, 6GT2600-0AA00)
01 hex
=
ISO transponder
02 hex
=
I-Code 1 and ISO transponder
03 hex
=
ISO-my-D (with SLG D10S only; the value 01 hex is set for ISO-my-D with
SLG D11S / D12S)
04 hex
=
ISO-FRAM (with SLG D11S/D12S only; the value 01 hex is set for ISO-
FRAM with SLG D10S) *
=
FB requires 6 S7 cycles per command
=
Depending on the ASM type and the overall configuration, the number of S7
cycles can be reduced to 3 per command
=
Depending on the ASM type and the overall configuration, the number of S7
cycles can be reduced to 2 per command
Description
Parameterizing
3.1 Parameter data block