Programming communications modules
B.4 Command and acknowledgement telegrams
Command table
Comma
Comman
nd
d
code
code
chained
[hex]
[hex]
0
1
41
2
42
3
43
4
44
SLG STATUS
6
-
8
48
A
4A
B
4B
MDS-STATUS Returns the properties of the transponder in the result
110
Command
RESET
CM is reset. The active command is terminated.
(If a tag command was terminated with RESET, the reset acknowledgment reports
error 1F.)
The RESET command can be used to switch the CM to various operating modes.
WRITE
Write data block to transponder
READ
Read data block from transponder
INIT
This command is required when a new transponder is used that has not yet been
written to or after failure/replacement of the battery or when the transponder is to
be operated in ECC mode. The transponder is already initialized for normal use.
2 KB
32 KB
44 bytes
112 bytes
256 bytes
996 bytes
2000 bytes
20 bytes
8 KB
32 KB
64 KB
Returns as result the status byte, the selected reader and the ANZ_MDS_present_
bit. This command checks whether a reader is connected to the CM and, if so,
whether it is functioning and ready for operation. An appropriate error is reported, if
necessary. With MOBY U various diagnostic data can be fetched from the reader.
NEXT
The command is not supported by the systems described here MOBY U/D, RF200
and RF300.
END
Terminate communication with the transponder (MOBY U only)
SET-ANT
MOBY U/D, RF200 or RF300 only:
This command turns the antenna field on the reader off and on again.
Description
Tag type
RAM
(MOBY U)
RAM
(MOBY U)
I-Code
(MOBY D)
I-Code SLI
(MOBY D)
Tag-it HF-I
(MOBY D)
my-d
(MOBY D)
FRAM
(MOBY D)
EEPROM
(RF300)
FRAM
(RF300)
FRAM
(RF300)
FRAM
(RF300)
Function Manual, 07/2012, J31069-D0166-U001-A4-7618
INIT duration
Memory size + 1
(normal)
approx. 1 s
00 08 00
approx. 1.5 s
00 80 00
approx. 0.4 s
00 00 2C
approx. 0.5 s
00 00 70
00 01 00
approx. 1 s
approx. 3 s
00 04 00
approx. 3 s
00 07 D0
approx. 0.2 s
00 00 14
0.9 s
00 20 00
3.6 s
00 80 00
7.2 s
00 FF 00
FB 45 for MOBY U, MOBY D, RF200, RF300