Figure 4-2
If the project is downloaded to the hardware in this step (without a user program), the
SIMATIC CPU and the PROFIBUS must change to RUN. If this is not the case, continue
troubleshooting PROFIBUS/PROFINET (check the PROFIBUS address settings on the
communications module or the IP address with PROFINET against the configuration in HW
Config).
3rd Step: Set the properties of the communications module
You can set the basic function of the communications module in the object properties of the
module (e.g. MOBY U, serial baud rate). The object properties are shown in one of the
following windows. The possible options are shown in the drop-down lists.
Figure 4-3
FB 45 for MOBY U, MOBY D, RF200, RF300
Function Manual, 07/2012, J31069-D0166-U001-A4-7618
Example of a hardware configuration
Configuring the object properties
Commissioning
43