Siemens SIMATIC Ident Function Manual page 33

For moby u, moby d, rf200, rf300
Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

SLG STATUS
Table 3- 10
SLG status
Command
sub_command
[hex]
04
01 = status after UDT 110
02 = status after UDT 120
(last commands)
03 = status after UDT 130
(error messages)
04 = status after UDT 140
(transponder in field)
05 = status after UDT 150
(communication quality)
06 = status after UDT 280
(diagnostics data)
You will find the UDT description in the section "UDTs of FB45".
1)
END
Table 3- 11
Terminate communication with the transponder (MOBY U)
Command
sub_command
[hex]
08
00 = Processing with
transponder has
terminated
01 = Processing pause
with the transponder
MOBY U:
1)
This command is recommended when the selected scanning_time is greater than 0 (standby time). Use of this command
optimizes the life of the transponder battery. Before another transponder command can execute, the sleep_time of the
transponder must first expire.
FB 45 for MOBY U, MOBY D, RF200, RF300
Function Manual, 07/2012, J31069-D0166-U001-A4-7618
length
[hex]
[dec]
1)
1)
1)
1)
length
[hex]
[dec]
1)
address_MDS
[hex]
Pointer to the result.
The result is indicated
with the
corresponding UDT
(see sub_command)
address_MDS
DAT_DB
[hex]
Parameterizing
3.2 RFID commands
DAT_DB
[dec]
MOBY U/D,
RF200 and RF300
MOBY U
MOBY U
MOBY U
MOBY U
RF300
Note
[dec]
ANZ_MDS_present is
reset.
ANZ_MDS_present
remains set.
Note
33