Error messages and troubleshooting
5.2 Error messages
NOTICE
When several error occur with chained commands, the "error variable" always indicates the
first error detected.
error_MOBY
The ERR LED of the reader flashes when there are error messages. Some errors are also
indicated by the flashing ERR LED of the CM.
Table 5- 2
Error code
(B#16#...)
48
Error messages of the communication module/reader using the "error_MOBY" variable
Flashing of
ERR LED
00
No error
Default value if everything is ok.
1x
No error
CM has started up and is waiting for an init_run.
01
2x
Presence error: The tag has moved out of the transmission window of
the reader. The command was executed only partially.
Read command: No data are transmitted to FB 45.
Write command: The tag that has just left the field contains an
incomplete data record.
The next command is automatically executed on the next tag. A
read/write command is possible.
02
2x
Presence error: A tag has passed by a reader without being processed
by a command.
This error message is not reported immediately. Instead, the CM is
waiting for the next command (read, write). This command is
immediately replied to with this error. This means that a read or write
command is not processed. Only the next command is executed
normally by the ASM again.
An init_run from FB 45 also resets this error state.
The operating distance from reader to tag is not being kept to.
Configuration error: The data record to be processed is too large (in
dynamic mode)
Function Manual, 07/2012, J31069-D0166-U001-A4-7618
Description
FB 45 for MOBY U, MOBY D, RF200, RF300