Parameterizing
3.2 RFID commands
SET-ANT
Table 3- 12
Switch antenna of reader ON/OFF
Command
sub_command
[hex]
0A
01 = antenna on
02 = stand-by; antenna off
This command is not needed for normal operation because, when a reader is turned on, its
antenna is always on.
The antennas must be turned off if two sensitive readers are positioned very close to each
other. The application software must ensure that only one antenna is on at a time.
MDS-STATUS
Table 3- 13
Transponder status and diagnosis
Command
sub_command
[hex]
0B
00 = status and
diagnosis
01 = type and write
protection status for
RF300 tags
02 = diagnostic data
03 = Type and write
protection
ISO tags
*
SLG D10S only
)
34
length
[hex]
[dec]
length
[hex]
[dec]
-
address_MDS
[hex]
address_MDS
[hex]
Today's date
(week/year) for
calculating the battery
life (e.g. 1401 hex =
20th week of the year
2001)
-
Function Manual, 07/2012, J31069-D0166-U001-A4-7618
DAT_DB
[dec]
The antenna on/off command
cannot be started by
command repetition (see
section "Command repetition
(Page 37)").
DAT_DB
[dec]
Pointer to result.
MOBY U only
The result is
(see section "The UDTs of
presented with
FB 45 / FC 45 (Page 74)")
UDT 100.
Pointer to result.
RF300
The result is
(see Section "UDTs of
presented with
FB 45")
UDT 260.
Pointer to result.
RF300
The result is
(see section "The UDTs of
presented with
FB 45 / FC 45 (Page 74)".)
UDT 270.
UDT 230
RF300 with ISO
transponders
RF200, MOBY D *
FB 45 for MOBY U, MOBY D, RF200, RF300