Table of Contents

Advertisement

4.2

Clock

Features of real-time clock
The following table lists the properties and functions of the SIMOTION D clock.
Table 4- 13
Features
Type
Default setting when delivered
Accuracy
With supply voltage on
With supply voltage off
Backup time at least
Charging time
Backup
With power OFF
In the power OFF state, the SIMOTION D clock continues to run during the the backup time
(with the exception of the software clock). The buffer is recharged in the power ON state.
An error message is output if the backup function is defective. When the power is switched
ON, the clock then resumes at the time set at the factory.
If the SIMOTION D4x5 is reset to its factory setting, the clock is also reset to the "default
setting when delivered".
SIMOTION D4x5
Manual, 02/2012
Clock features
0 to 55° C
25° C
-20° C to 70° C
Meaning
Hardware clock (integrated "realtime clock")
DT#1992-01-01-00:00:00
Max. deviation per day:
±9 s
±2 s
+2 s to -9 s
5 days (at 0 to 25° C)
with fan/battery module 3 years
A few minutes
Maintenance-free SuperCap or battery in fan/battery
module
Technical data
4.2 Clock
65