Component
SMx sensor modules
Motors with DRIVE-CLiQ
interface
DMC20/DME20 DRIVE-CLiQ hub ...enables the number of DRIVE-CLiQ interfaces to be increased
Note
You can find detailed information about components in the SINAMICS S110/S120 family of
products in the SINAMICS S110/S120 manuals.
Optional components
The functionality of the D4x5 Control Unit can be expanded by using one of the components
listed below.
Table 1- 6
Component
Communication Board Ethernet
CBE30
TB30 terminal board
The selected component is plugged into the option slot of the Control Unit.
Note
CBE30 can only be used in SIMOTION D4x5 Control Units.
CBE30-2 can only be used in SIMOTION D4x5-2 Control Units.
SIMOTION D4x5
Manual, 02/2012
Function
... enable acquisition of encoder data from connected motors via
DRIVE-CLiQ.
...allow simplified commissioning and diagnostics, as the motor
and encoder type are identified automatically.
and the creation of a star-shaped topology.
Optional components
Function
Communication via PROFINET IO with IRT and PROFINET IO
with RT
Terminal expansion, i.e. additional analog and digital I/Os
Description
1.2 System components