Manual Override

The Inline Shutoff Valve can be operated manually as follows in case of a loss of power:
Note that the SC904ZB Inline Shutoff Valve is intended for operation either fully closed or fully open.
Throttling operation is not recommended since the ball valve does not open or close proportionally.
Resetting
Factory Defaults
Step 1. Select the SC904ZB icon
from the SALUS Smart Home
dashboard . After the tile flips,
choose the device name in the
upper left .
Manual
Override
Button
Manual
Override
Lever
Module 2 – Wireless Accessories
SC904ZB Inline Shutoff Valve
Step 1. Press and hold the
Manual Override Button
Step 2. Move the Manual
Override Lever
to the
desired valve position .
Step 2. Scroll to the bottom
of the next screen and select
"Remove Shared Water Leak
Sensor . "
Multi-Function
Button
Status LED
Power
Adapter
.
Step 4. Unplug the power adapter to power off
the device .
Step 5. Hold down the Multi-Function Button while
re-connecting the power .
Step 6. Release the Button when the LED Indicator
turns solid green .
At this point, the valve has been reset to factory
default settings and will respond to pairing requests .
Step 3. Release the
Manual Override Button
to re-engage the
actuator motor .
Step 3. Notification that the
Sensor will be removed is
displayed . Press "Delete" to
continue . The SC901ZB Icon
will be removed from the
application .