Installation Instructions - Salus Connected Wireless System Manual

Table of Contents

Advertisement

Section 5

Installation Instructions

SALUS recommends locating the Window/Door Sensor on the window or door casing on the
handle side. The Magnet should be mounted on the window or door as close as possible to the
Sensor. To be UL compliant, the Sensor and Magnet must be mounted using the screws.
Step 2. Remove the SS912ZB
Sensor cover and use the screws
provided to attach the sensor at
the intended location .
Step 3. Open the Magnet case and use the screws provided to attach the magnet in the intended
location . Depending on relative position of the Door/Window in the frame, the included spacer may be
required (using the longer screws) to maintain the same height of the Sensor and Magnet .
Module 2 – Wireless Accessories
SS912ZB Slim Window/Door Sensor
Step 1. Identify location of the Sensor
and Magnet . MAKE SURE that the
bottom, flat end, of the sensor and
magnet are aligned and that the magnet
is on the right side (at grey indicator) .
NOTE: Proper installation may require the
Sensor to be mounted on the door or window
with the magnet mounted on the frame .
NOTE: If the installation cannot accommodate screw mounting,
use the double-sided adhesive mounting tape provided, by first
peeling the brown backing from the adhesive and attaching
it to the sensor . MAKE SURE the tamper switch on the back
of the device can move freely . Remove the white/red paper
backing and press the sensor into the intended location .
Step 4. Open and close the door or window, observing the
icon tile on the SALUS Smart Home dashboard . Make sure the
position of the window representation on the tile corresponds
to that of the door/window . It may take 1-2 minutes for the
application to respond . MAKE SURE that the Sensor or Magnet
does not interfere with opening and closing of the window .
5-4