Reaction To Cpu Stop - Siemens ET 200SP Manual

Technology module tm pulse 2x24v
Hide thumbs Also See for ET 200SP:
Table of Contents

Advertisement

Hardware Support Packages (HSP)
STEP 7
The Hardware Support Packages (HSP) are available for download on the Internet
(https://support.industry.siemens.com/cs/ww/en/view/23183356).
GSD file
The respective GSD file for the ET 200SP distributed I/O system is available for download on
the Internet:
● GSD file PROFINET IO (http://support.automation.siemens.com/WW/view/en/57138621)
● GSD file PROFIBUS DP (http://support.automation.siemens.com/WW/view/en/73016883)
4.3.3

Reaction to CPU STOP

You set the response of the channel to a CPU STOP in the parameters of the device
configuration.
Table 4- 7
Option
Output substitute
value
Continue opera-
tion
Technology Module TM Pulse 2x24V (6ES7138‑6DB00‑0BB1)
Manual, 05/2019, A5E35061186-AB
Response of channel to CPU STOP
Meaning
The channel outputs the configured substitute values at the digital outputs until
the next STOP-RUN transition of the CPU. You can configure the substitute val-
ue 1 for only one of the two digital outputs.
An active output sequence is stopped and the STS_ENABLE feedback bit is
reset.
The technology module is set to its startup state after a STOP-RUN transition.
Before you can start a new pulse output, you must reset the SW_ENABLE control
bit.
The channel continues to operate.
The digital outputs continue to switch according to the parameter assignment. An
active output sequence will thus be continued. If you have configured the hard-
ware enable, you can also start additional output sequences using DIn.0.
The configuration of the technology module is not reset after a STOP-RUN transi-
tion.
Configuring/address space
4.3 Pulse train mode
69