On Delay - Siemens ET 200SP Manual

Technology module tm pulse 2x24v
Hide thumbs Also See for ET 200SP:
Table of Contents

Advertisement

Configuring/address space
4.6 PWM with DC motor motor
4.6.1.4

On delay

You set the On delay from 0 s to 85 s with a precision of 1 µs in the hardware configuration.
In addition, you can change the On delay via the control interface by entering a new value in
SLOT as an integer (UDINT). In so doing, you use the MODE_SLOT control bit to choose
whether you want to apply a change once or cyclically:
MODE_SLOT = 0
MODE_SLOT = 1
Note
In isochronous mode, a configured On delay has no effect.
You can find additional information under Handling of the SLOT parameters (Page 139).
112
One-time change:
As soon as you write the value 2
value from SLOT is applied once as the On delay and kept until the next
change.
A change via SLOT takes effect at the next output sequence. An active
output sequence is not affected by the change.
Cyclic change:
When you write the value 18
value from SLOT in each case is applied cyclically as the On delay.
A change via SLOT takes effect at the next output sequence. An active
output sequence is not affected by the change.
Technology Module TM Pulse 2x24V (6ES7138‑6DB00‑0BB1)
in the corresponding output byte, the
D
in the corresponding output byte, the current
D
Manual, 05/2019, A5E35061186-AB