3700 Series Flat Panel Industrial PC

Hazardous Locations Control Drawing

The following control drawing applies to front panel ports only.
Class I, Division 2, Groups A, B, C and D, and Class II, Division 2, Groups F and G
Proface/Xycom Model
3712KPM(T) or
3715KPM(T)
Front Panel USB and
PS/2 Ports
(see note 1)
Notes:
1. Nonincendive Circuit Parameters:
2. Selected nonincendive Field Wiring Apparatus shall satisfy the following:
Nonincendive Field Wiring Apparatus
3. If the electrical parameters of the cable are unknown, the following values may be
used:
4. Nonincendive Field Wiring must be installed in accordance with Article
501.4(B)(3) of the National Electrical Code ANSI/NFPA 70.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Hazardous (Classified) Locations
USB Port (Pins 1 to 4)
V
= 5 VDC
oc
I
= 3.3 A
sc
C
= 10 uF
a
L
= 16 uH
a
V
max
I
max
C
+ C
i
cable
L
+ L
i
cable
Capacitance – 60 pF/ft
Inductive – 0.20 uH/ft
34
Warning
PS/2 Port (Pins 3 to 4)
Pro-face/Xycom Model 3715KPM
Chapter 2 – Installation
Nonincendive Field
Wiring Apparatus
V
= 5 VDC
oc
I
= 3.3 A
sc
C
= 10 uF
a
L
= 4 uH
a
and KPMT
V
oc
I
sc
C
a
L
a
143311 (H)