Agilent Technologies OmniBER OTN Series Performance Verification Manual page 88

Communications performance analyzer
Hide thumbs Also See for OmniBER OTN Series:
Table of Contents

Advertisement

Verification.book Page 85 Monday, January 19, 2004 1:40 PM
Verification Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
3 Press <Menu>, select Tx/Rx > Transmitter settings and set
the Signal Mode to SDH. Now set the Signal Rate to STM-1,
and Interface to Electrical.
4 Load the 155Mb_ITU_0.msk test mask and check the 'zero'
pulses are within the mask. See examples.
5 Also check the 'ones' pulses (normal & inverted) by loading
and checking against the 155Mb_ITU_1.msk and
155_ITU_1_INV.msk test masks (see examples).
STM-1 All Zeros Mask Test