Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
1 Check all connections to make sure that all the correct
loopback connections are in place and Optical Attenuators
are fitted as required.
2 Be suspicious of any optical interface failures and if
necessary clean all optical connections with a recognized
cleaning kit before retrying the self test.
3 Carefully check the Error Code/Messages, in particular
ensure all of the required loopback connections are made.
4 If the problem persists then contact your local Agilent
Service Office or representative.
Tips and Checks to Confirm Correct Optical Loopback
• Make sure connectors are located in key/notch of the port
connectors to ensure full insertion.
• Check Transmitter and Receiver are set to the same Signal
Rate and that the correct Laser is On when test is being Run.
• Press <Smart Test>, choose Shortcuts > Optical Power then
press <Select>. Check the Received signal level is in the
Green BER measurement power range.
• Ensure all optical connections are clean and fully connected
with no sharp bends or twists in the optical patch cord.
Check the Optical Cord and Attenuator are not damaged
and/or substitute with equivalent.
• If problem relates to a particular operation Rate, Mode or
Function perform a manual Back to Back operation check to
confirm signal path.