Verification.book Page 33 Monday, January 19, 2004 1:40 PM
Verification Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
3 Connect the 52 Mb/s Optical Out Port (1310/1550 nm) to the
oscilloscope via an optical attenuator. Set the attenuator to
provide approximately 6dB attenuation, (see Note). Also
connect the TX Eye Clock (52 Mb/2.5 Gb/s) to the
oscilloscope Trigger input.
Optical signal should be attenuated to ensure specified maximum input for
NO TE
86103A (–4 dBm) is not exceeded. To ensure this, Set the 8156A to 3 dB,
(typical 8156A attenuator insertion loss of approximately 3 dB), giving
approximately 6 dB total attenuation.