Verification.book Page 56 Monday, January 19, 2004 1:40 PM
1
Performance Tests
56
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
12 Disable the optical attenuator then disconnect the Optical
signal from the OmniBER OTN Optical IN port and connect
to the power meter. Re-enable the optical attenuator.
13 Check the power meter reading is between:
–8.5 dBm and –7.5 dBm
Verification Manual