Electrical Requirements - Oracle X8-8 Installation Manual

Table of Contents

Advertisement

Electrical Requirements

Electrical Requirements

The server uses AC power. The server can operate effectively over a range of voltages and
frequencies.
The following table contains the power supply specifications for Oracle Server X8-8.
Note -
power numbers for the power supply used in the system. The numbers are not a rating of the
actual power consumption of the system. For up-to-date information about power consumption,
go to the Oracle Power Calculators web site
power-calculators/, and click the Oracle Server X8-8 link.
Parameter
Voltage (nominal)
Input current (maximum)
Frequency (nominal)
Maximum power
consumption
Maximum heat output
Caution -
input voltage levels or in input power frequency ranges are exceeded. Electrical disturbances,
such as the following, might damage the system:
Fluctuations caused by brownouts
Wide and rapid variations in input voltage levels or in input power frequency
Electrical storms
Faults in the distribution system, such as defective wiring
To protect your server from such disturbances, use a dedicated power distribution system,
power-conditioning equipment, and lightning arresters or power cables for protection from
electrical storms.
See the following additional power specifications.
18
Oracle Server X8-8 Installation Guide • June 2019
The power dissipation numbers listed in the following table are the maximum rated
Specification
200-240 VAC
■ 23 A @ 200 to 240 VAC
■ 12 A max per cord
50/60 Hz
■ Single 4-socket –1980 W
■ Dual 4-socket – 3950 W
■ Single 8-socket – 3880 W
13,475 BTU/Hr
Servers must have a reliable power source. Damage to the server might occur if the
https://www.oracle.com/it-infrastructure/