Configure Raid On Oracle Storage 12 Gb Sas Pcie Raid Host Bus Adapter, Internal 16 Port - Oracle X8-8 Installation Manual

Table of Contents

Advertisement

Configure RAID on Oracle Storage 12 Gb SAS PCIe RAID Host Bus Adapter, Internal 16 Port

Configure RAID on Oracle Storage 12 Gb SAS PCIe RAID
Host Bus Adapter, Internal 16 Port
The Oracle Storage 12 Gb SAS PCIe RAID Host Bus Adapter, Internal 16 Port manages the
HDDs and SSDs in your system. When the system is shipped, the HDD and SSD drives are
configured into RAID 0 volumes. Use this procedure to reconfigure these into RAID volumes
according to your performance and redundancy needs.
Caution -
not recommended. An array with both HDDs and SSDs operates at HDD speed, which is
significantly lower than the speed of the SSDs.
Configure the server for a one-time boot to BIOS.
1.
Access the Oracle ILOM web interface.
a.
b.
Navigate to Host Management → Host Control.
c.
Select BIOS from the drop-down list, and select Save.
This causes the server to boot to BIOS on the next boot.
2.
Access a system console.
For more information, see
refer to Oracle X8 Series Servers Administration Guide at
x86admindiag/docs.
Power on or reset the server.
3.
For example, to reset the server:
From the local server, press the On/Standby button on the front panel of the server for
approximately 1 second to power off the server, and then press the On/Standby button again
to power on the server.
From the Oracle ILOM web interface, select Host Management → Power Control, and
in the Select Action list box, select Power On. Click Save, and then click OK.
From the Oracle ILOM CLI, type: reset /System.
The system boots to the BIOS Setup Utility.
92
Oracle Server X8-8 Installation Guide • June 2019
Degraded Performance. Combining HDD and SSD drives in the same array is
"Redirect Host Server Desktop or Storage Devices" on page 83