Device Description - WAGO -I/O-SYSTEM 750 750-481/003-000 Manual

2ai rtd ex i 2-channel analog input module for resistance sensors, ex i
Table of Contents

Advertisement

WAGO-I/O-SYSTEM 750
750-481/003-000 2AI RTD Ex i
Po
s: 16 /Alle Serien (Allgemeine Module)/Überschriften für alle Serien/Gerätebeschreibung - Überschrift 1 @ 3\mod_1233756084656_21.doc @ 27096 @ 1 @ 1
3

Device Description

Po s: 17.1 /Serie 750 (WAGO-I/O-SYSTEM)/Gerätebeschreibung/Beschreibung/Anwendung/AI/Anwendung 750-04xx AI Ex i RTD/NTC parametrierbar @ 5\mod_1245914618593_21.doc @ 36006 @ @ 1
The Analog Input Module 750-481/003-000 (2AI RTD Ex i) processes signals
from resistance sensors that are operating in hazardous environments of Zones 0
and 1. It allows the connection of Pt and Ni resistance sensors potentiometers
Depending on the operating mode, the resistance value is converted to a
temperature or directly sent out by the module. A microprocessor within the
module is used for converting and linearizing the measured resistance value into a
numeric value proportional to the temperature of the selected resistance sensor.
The operating mode can be set by using the WAGO-I/O-CHECK 2 start-up and
diagnostic tool (Item No.: 759-302). The default setting is Pt 100.
Po s: 17.2 /Serie 750 (WAGO-I/O-SYSTEM)/Gerätebeschreibung/Beschreibung/Anwendung/Hinweise/Warnung: Ex i Installation des WAGO-I/O-SYSTEM 750 nur in Zone 2 oder im nicht-ex-Bereich @ 5\mod_1245851655116_21.doc @ 35947 @ @ 1
Installation only in zone 2 or in non-hazardous environments!
The installation of the WAGO-I/O-SYSTEM 750 fieldbus couplers/ controllers
and I/O modules is only to be done in zone 2 or in non-hazardous environments.
Po s: 17.3 /Serie 750 (WAGO-I/O-SYSTEM)/Gerätebeschreibung/Beschreibung/Anwendung/AI/Anwendung 750-04xx AI Ex i - Nur Messumformer ohne eigene Spgvers. anschliessen @ 5\mod_1245849943157_21.doc @ 35934 @ @ 1
To fulfill Ex i regulations, only passive transducers, that means without their own
voltage supply, like adjustable resistances, pressure, flow and level meters, may
be connected to the input module.
Po s: 17.4 /Serie 750 (WAGO-I/O-SYSTEM)/Gerätebeschreibung/Beschreibung/Anwendung/AI/Anwendung 750-04xx Messumformerversorgung direkt aus der Busklemme @ 5\mod_1246287878058_21.doc @ 36324 @ @ 1
The transducers are directly supplied with 24V from the I/O module.
Po s: 17.5 /Serie 750 (WAGO-I/O-SYSTEM)/Gerätebeschreibung/Beschreibung/I/O-Beschreibung/AI/I/O-Beschreibung 750-04xx 2 AI RTD/NTC @ 7\mod_1274420216920_21.doc @ 56930 @ @ 1
The module has two input channels allowing the direct connection of two 2- or 3-
wire resistance sensors.
For example, two 3-wire sensors can be connected either to +R1, RL1 and -R1 or
to +R2, RL2 and -R2.
Po s: 17.6 /Serie 750 (WAGO-I/O-SYSTEM)/Gerätebeschreibung/Beschreibung/I/O-Beschreibung/Hinweise/Verweis auf Kapitel "Anschlüsse" @ 8\mod_1276775378035_21.doc @ 57956 @ @ 1
The assignment of the connections is described in the "Connections" section.
Po s: 17.7 /Serie 750 (WAGO-I/O-SYSTEM)/Gerätebeschreibung/Beschreibung/I/O-Beschreibung/Hinweise/Verweis auf Kapitel "Geräte anschließen - Anschlussbeispiel(e)" @ 5\mod_1246015203281_21.doc @ 36298 @ @ 1
Connection examples are in the "Connecting devices - connection examples"
section.
Po s: 17.8 /Serie 750 (WAGO-I/O-SYSTEM)/Gerätebeschreibung/Beschreibung/I/O-Beschreibung/AI/I/O-Beschreibung 750-04xx AI Gemeinsamer Schirmanschluss @ 7\mod_1274786880908_21.doc @ 56960 @ @ 1
Each input channel of a module has a shield (screen) connection (S).
Po s: 17.9 /Serie 750 (WAGO-I/O-SYSTEM)/Gerätebeschreibung/Beschreibung/I/O-Beschreibung/AI/I/O-Beschreibung 750-04xx AI Schirmanschluss Kontakt mit Tragschiene @ 5\mod_1246367742653_21.doc @ 36360 @ @ 1
The shield connection is fed directly to the carrier rail and contact is made
automatically by snapping the module onto the rail.
Po s: 17.10 /Serie 750 (WAGO-I/O-SYSTEM)/Gerätebeschreibung/Beschreibung/LED-Anzeige/LED Zustand Betrieb @ 5\mod_1245391732046_21.doc @ 35668 @ @ 1
The "ready" state of the respective channel and the internal data communication is
indicated by a green function LED.
Po s: 17.11 /Serie 750 (WAGO-I/O-SYSTEM)/Gerätebeschreibung/Beschreibung/LED-Anzeige/LED Fehler Kurzschluss/Drahtbruch/Bereichsüber-/unterschreitung @ 5\mod_1245391942765_21.doc @ 35672 @ @ 1
A red fault LED per channel indicates a wire break, a short circuit or that the
signal is outside the measuring range.
Po s: 17.12 /Serie 750 (WAGO-I/O-SYSTEM)/Gerätebeschreibung/Beschreibung/LED-Anzeige/Verweis auf Kapitel "Anzeigeelemente" @ 5\mod_1246010525000_21.doc @ 36194 @ @ 1
The meaning of the LEDs are described in the chapter „Display Elements".
Po s: 17.13 /Serie 750 (WAGO-I/O-SYSTEM)/Wichtige Erläuterungen/Sicherheitshinweise/Warnung/Warnung: Ex i Einspeisung @ 4\mod_1241505512875_21.doc @ 32293 @ @ 1
Manual
1.1.0
Device Description
13