Rockwell Automation Allen-Bradley SynchLink 1756-DM Series Design Manual page 92

Table of Contents

Advertisement

A-6
Publication 1756-TD008A-EN-P - August 2002
Table 1.4
1751-SL4SP SynchLink 4-Port Splitter Block Specifications
Communication Rate
Splitter Block Power Consumption
Environmental Conditions
1
Operating Temperature
Storage Temperature
Relative Humidity
Shock
Operating
Non-Operating
Vibration
Fiber Optic Cable
Fiber Type
Fiber Termination Type
Assemblies
Maximum Length
Minimum Length
Agency Certifications
1
This product must be mounted within a suitable system enclosure to prevent personal injury resulting from
accessibility to live parts. The interior of this enclosure must be accessible only by the use of a tool. This
industrial control equipment is intended to operate in a Pollution Degree 2 environment, in overvoltage
category II applications, (as defined in IEC publication 664A) at altitudes up to 2000 meters without
derating.
5M bit/s
0.300 A @ 5.1V dc
5V dc input from 1751-SLBA
0ºC - 60ºC (32ºF - 140ºF)
-40ºC - 85ºC (-40ºF - 185ºF)
5 to 95%, 0ºC - 60ºC non-condensing
30g peak acceleration, 11 ( ± 1)ms pulse width
50g peak acceleration, 11 ( ± 1)ms pulse width
Tested 5g @ 10-500Hz per IEC 68-2-6
200/230 micron HCS (Hard Clad Silica)
Versalink V-System
Cable assemblies can be ordered from Rockwell
Automation, catalog number 1403-CFxxx
(xxx = length in meters); or from Lucent
Technologies, Specialty Fiber Technologies division.
300m
1m
Listed Industrial Control Equipment
Certified Process Control Equipment
Certified Class I, Division 2, Groups A, B, C, D
Marked for all applicable directives
Marked for all applicable acts
N223