4-12
Master Node
ControlNet
Publication 1756-TD008A-EN-P - August 2002
Daisy Chain Topology Configuration #4
In this configuration, PowerFlex 700s drives are the master, center and
end nodes.
Figure 4.7
Center Node
SynchLink
Table 4.8 lists more information about this configuration.
Table 4.8
Category:
Time synchronization
Data transfer
Restrictions
Typical applications
(1)
For the PowerFlex 700S drives, the drive's VPL microprocessor must move the buffered data. For more
information, see page 1-7.
Center Node
Explanation:
Master -
PowerFlex 700S drive
Slaves
-
PowerFlex 700S drives
The SynchLink node clocks and the VPLs are synchronized across
all nodes.
· Typically, this configuration is used to transfer direct data.
· If you want to pass buffered data, the local controller at
each node must pass the data.
· Axis data is not supported in the configuration.
· You can use a maximum of 10 SynchLink connections.
· Drawing application
· Torque sharing application
· Master reference generation
End Node