The SynchLink cable system is designed for use with a 200 micron
(step index multi-mode) Hard Clad Silica (HCS
coated with a patented hard polymer cladding that provides higher
tensile strength, greater resistance to moisture, and lower
microbending losses than conventional coatings.
HCS Cable Construction
The HCS cable is the core of the HCS fiber and is reinforced with
aranid yarn-strength members and covered with a PVC outer jacket.
The cable specification is shown in Table B.3.
Table B.3
HCS Cable Specification
Cable Construction
mt
Fiber Core Diameter (
)
Fiber Part Number
Attenuation @ 650nm (dB/km)
Outer Cable Diameter (mm)
Outer Jacket Material
Standard Jacket Color
Cable Weight (kg/km)
Minimum Short-Term Pull Tension (lbs/N)
Maximum Long-Term Tension (lbs/N)
Break Strength (lbs/N)
Minimum Bend Radius (mm)
Operating Temperature (
C)
o
Storage Temperature (
C)
o
Flammability Rating
Lucent Technologies, Specialty Fiber Technologies manufactures the
HSC fiber, fiber optic cable, and cable assemblies.
Ò
) fiber. HCS fibers are
Simplex
200
CF01493-10
<12
2.2
PVC
Blue
6.1
23/102
5/22
34/151
15
-40 to +85
-40 to +85
OFNR