9. TROUBLESHOTING

Problem
Cause
Does not heat
No power
Switch set to -OFF-
Thermoprobe intervention
Thermostat on "0"
Mixing paddle
No power
does not turn
The driving shaft is not properly in
place
Motor fault
On/off switch on (0)
Tap leaks
It has not been fit correctly
The outlet and rubber are dirty
The sealing gasket needs replacing
Water is
Temperature too high
escaping from
The sealing gasket of the level tube
the level tank
needs replacing
The water level is above the MAX
indication when the machine is at
room temperature
Product leaks
The bowl has not been fit correctly in
from the bottom
place
of the
The seal needs replacing
transparent
bowl
The thermometer
Flat battery
does not show
Probe malfunction
temperature
Machine
The water level in the boiler tank has
shutdown
fallen below the minimum level with
resulting machine shutdown
No water in the boiler tank
If the machine malfunctions due to causes other than those listed in this table or the proposed remedies do not solve
the problem, contact a specialized technician.
Remedy
Make sure that the machine is plugged in peoperly
Set the switch to -ON-
Reset the thermal protector as directed in section 6.1.
Adjust the thermostat
Make sure that the machine is plugged in properly
Remove the shaft and then insert it correctly as directed
in section 7.5.2.
Contact service personnel
Press the switch on
Empty the machine and fit the tap as directed in section
7.5.3.
Empty the machine and clean the entire tap throughly;
fit it back on the machine as directed in section 7.5.1.
Contact service personnel
Lower the temperature
Contact service personnel
Allow the machine to cool down and empty the boiler until
reaching the level indicated
Empty the machine, remove the bowl and fit in place
according to the instructions provided in section 7.5.2.
Contact service personnel
Replace the battery, paragraph 7.9.
Contact service personnel
Top up the boiler tank, if a level sensor is fitted
Call for a specialized technician to reset the machine
Top up the boiler tank, if a level sensor is fitted
Call for a specialized technician to reset the machine