Reading The Maximum/Minimum Values Of Measured Data; Recalculating The Maximum And Minimum Values (Restart Function) - Magnescale LY71 Instruction Manual

Counter unit
Hide thumbs Also See for LY71:
Table of Contents

Advertisement

1. Basic Operation

1-4. Reading the Maximum/Minimum Values of Measured Data

1
Press the
key on counter display A.
........ This clears the display data for all counter displays to zero.
2
Move the measuring unit in the positive or negative direction to start measurement.
3
The data is updated after measurement is completed.
........ Counter display B: The maximum value for the distance moved
........ Counter display C: The minimum value for the distance moved
Read and confirm the display data.

1-5. Recalculating the Maximum and Minimum Values (Restart Function)

Pressing the
key recalculates the maximum and minimum values from
that point.
1
Press the
key.
2
Move the measuring unit.
........ The maximum and minimum values are recalculated, and the
display data is updated.
∗ Recalculation is also possible by pressing the
recalculation starts from zero. (See "1-4. Reading the Maximum/Minimum Values of Measured Data".)
∗ Recalculation is also possible using the preset operation. (See "1-7. Setting Values to the Display (Preset
Function).")
∗ Restart is also possible with an external signal. (See "2-16-9. Operating restart from an external device".)
1-2
(E)
in step 2 is displayed. (The MAX lamp lights
on.)
in step 2 is displayed. (The MIN lamp lights
on.)
key instead of the
key. However, in this case, all
LY71

Advertisement

Table of Contents
loading

Table of Contents