4-3-1. Display at power ON

This sets the display mode when the power is turned on.
display
: This setting can be used as an alarm to indicate that power supply was interrupted.
COUNT display : This setting enables immediate use after the power is turned on. However, when the master
calibration function is set, the counter unit waits to go past the reference point.

4-3-2. Display resolution and polarity

The initial value is the same as the measuring unit resolution set by the basic settings. When the measuring
unit resolution is changed, the display resolution is also initialized to the same resolution.
Also set the display polarity when setting this item.

4-3-3. Display axis, and display data at power ON

You can set the axis (first axis input, second axis input, addition axis) displayed in each counter display (A/
B/C) and the data (current value, maximum value, minimum value, peak-to-peak value (maximum value _
minimum value)) displayed at power ON.
Factory settings
Counter display A: Current value of the first axis input
Counter display B: Maximum value of the first axis input
Counter display C: Minimum value of the first axis input
The contents set here become the display data at power ON.
Setting method
1
Press the
key of the counter display (A/B/C) to be set, and select the axis to be displayed.
(First axis) →
2
Press the
key.
3
Press the
key to select the data displayed at power ON.
(Current value) →
(Maximum value - Minimum value)
4
Press the
key.
Changing the display data during operation
Operating Manual.)
• Display data can be switched during the operation when the display data are from the same input axis.
However, input axis whose data are displayed cannot be switched. When the display axis must be switched,
make the change with the advanced settings.
• Display data set by the advanced settings is displayed when the power is turned back on.
LY71
(Second axis) →
(Addition axis)
(Maximum value) →
(See "1-6. Switching the Display Data" in the
(Minimum value) →
4. Settings
4-9