2. Applied Operation
2-16. External Input/Output
2-16-1. Outputting a signal when going past the zero point
When going past zero in incremental value mode, the signal results are output.
Outputs 1, 2 : Counter display A output signal
Outputs 3, 4 : Counter display B output signal
∗ Counter display C is a reference display, and so output saving is not possible.
➔ Installation manual "4-3. Advanced Settings" (General-purpose output)
2-16-2. Resetting with an external signal
Connections are required.
Ex. RESET A: A-axis reset
Ex. RESET B: B-axis reset
➔ Installation manual "4-3. Advanced Settings" (General-purpose input)
2-16-3. Switching the display data from an external device
Connections are required.
Ex. IN A : Input signal for counter display A
Ex. IN B: Input signal for counter display B
Ex. IN C: Input signal for counter display C
➔ Installation manual "4-3. Advanced Settings" (General-purpose input)
2-16-4. Sending alarm signals to an external device
Connections are required.
OUT A1, OUT A2 : Counter display A output
OUT B1, OUT B2 : Counter display B output
∗ Counter display C is a reference display, and so output saving is not possible.
➔ Installation manual "4-3. Advanced Settings" (General-purpose output)
2-8
LY71
(E)