Operation
The EN 60335-2-53 "Specific requirements for sauna heating devices" allows the follo-
wing maximum heating times:
Max. heating time
more than 12 hours
max. 12 hours
max. 6 hours
Table: 7 Maximum heating time
The control devices are delivered with a maximum adjustable heating time of 6 hours. If
you need heating times exceeding 6 hours, please contact the installer or the dealer of
your sauna system.
5.4.2
Maximum allowed heating time
After starting a mode, the remaining heating time is displayed in place of the full heating
time. The heating time can be changed only in standby mode.
The EN 60335-2-53 "Specific requirements for sauna heating devices" allows the follo-
wing maximum heating times:
Max. heating time
more than 12 hours
max. 12 hours
max. 6 hours
Table: 8 Maximum heating time
The control devices are delivered with a maximum adjustable heating time of 6 hours. If
you need heating times exceeding 6 hours, please contact the installer or the dealer of
your sauna system.
5.5
Day timer
1.
2.
3.
4.
5.
6. For turning off the timer, please turn off the control unit or press mode-key once for
20
Operating manual Steam bath control Series FCU2000/FCU3000/FCU4000_ B_FCUxxxx-Steam_EN / Version V 2.03
NOTE!
The timer may not be enabled without additional safety measures by your
service technician and therefore it can be disabled
appear).
Press the
-key until the symbol
Adjust desired time (see above)
Press the
-key to adjust the value.
Press the mode-key (flashes)
Symbol
flashes.
starting and once again for stopping.
Description
Public cabins which are supervised by trained
personnel.
Hotels, apartment blocks, etc.
All other cabins / private households
Description
Public cabins which are supervised by trained
personnel.
Hotels, apartment blocks, etc.
All other cabins / private households
(adjust timer) lights up.
(the
menu does not