Table of Contents Table of Contents Safety..........................5 Explanations of symbols ................5 Demands on the operator and technicians...........5 Intended use ....................6 Changes and modifications ................7 Operational safety and special dangers ............7 Identification ........................8 Nameplate ....................8 Technical Data:........................8 Design and function......................9 Function ......................9 4.1.1 Steam ......................9 4.1.2...
Page 4
Table of Contents "Basic settings" - general ................28 6.1.1 Time and Weekday................28 6.1.2 Weekly timer ON/OFF (only for FCU4xxx) ........... 29 6.1.3 Program the weekly timer ..............29 6.1.4 Select program (only for FCU4xxx) ............31 6.1.5 Adjust display lighting (not for FCU2xxx)..........32 6.1.6 Adjust display contrast (only for FCU4xxx)...........
Safety Safety Explanations of symbols Warnings Warnings in this operating manual are indicated through symbols. The instructions are introduced through signal words, which express the degree of danger. Follow these instructions strictly and take care to avoid accidents, personal injuries and property damage.
Safety – their physical, sensory or mental abilities or – Lack of experience and / or knowledge which prevent the safe use of the device without supervision or instruction. Children playing with the device. The operating instructions are to be read carefully before switching on the unit! To en- sure safe operation and safe working practices you must comply with all the given safety and handling instructions.
Safety Any damage claims which arise due to improper use are excluded. Only the user is re- sponsible for damages caused by improper use. 1.3 Changes and modifications Changes and modifications to the steam bath control or to the installation could lead to unexpected dangers.
Identification Improper WARNING! operation Improper operation can result in serious injuries! Therefore: – read and note the operating manual. Identification Nameplate The nameplate is located on the control unit on the left side: Art Nr Spg.: RoHS Geräte Nr.: conform Fig.1 Control unit nameplate Type designation Company logo...
Design and function Design and function Function Depending on the model, the control unit is suitable for the following modes: Steam Aroma Seat heating (optional) 4.1.1 Steam In the "Steam" mode, the cabin is heated to the desired temperature (set point tempera- ture) with the help of a vaporiser.
Design and function Operating and display elements 4.2.1 FCUxxxx-Steam design and FCU-Steam design glass Fig. 2: View: Operation FCUxxxx-Steam design and FCUxxxx Steam design glass Status display "Steam generator" "Set temperature" symbol Status display "Aroma" "Set flavour" symbol Status display "Seat heating" "Set or remaining heating time"...
Design and function 4.2.2 Control keys steam bath control The steam bath control is equipped with the following control keys: Description "Steam" key Depending on the status of the green lamp, the "Steam" key has different functions. Status lamp next to the key Meaning Flashes Bathing mode “Steam”...
Page 12
Design and function Description "Basics menu settings" key Call "Basic settings menu". Navigate upwards within the menu. Navigate one line upwards in the display. Increase the value by one. Select option Navigate downwards within the menu. Navigate one line downwards in the display. Reduce the value by one.
Design and function 4.2.3 Explanation of the display Fig. 3: Explanation of the FCU2xxx display indicates which symbol or status display is currently enabled. Colour wheel indicates whether colour light option is available. Auto / manual 11-14 Colour lamps 1-4 Supply to the colour box Thermometer is visible as soon as a value is shown on the bar graph.
Design and function Display symbols The following symbols can appear in the display of the FCU4x00 control: Display elements Description Temperature Aroma Heating time Remaining heating time Start time Light Colour light ...
Operation Operation Safety and instructions Electric DANGER! potential Danger to life due to electric potential! Touching live parts can cause immediate danger to life. Therefore: – Control unit should be opened only by authorised electricians. – Electrical work on the machine should be carried out only by qualified electricians.
Operation NOTE! The temperature values displayed on additional thermometers in the cabin can deviate from the displayed values on the control. This could be due to the following reasons: Depending on the cabin, the temperature differences from the floor to the ceiling can be considerably.
Operation 5.2.3 Select or start the mode Mode Turn on steam bath control according to chapter 5.2.1. select The green lamp of the "Steam bath" mode flashes. Press the key for the "Steam bath" mode. The lamp flashes. Mode was started. Description Steam bath mode Table: 5 Mode control keys...
Operation The symbol (adjust heating / remaining heating time) lights up. Depending on the status of the lamp next to the mode key, adjust the heating time or the remaining heating time. → See page 18, chapter 5.4. 10. Press the key.
Operation Heating time Remaining heating time The heating time is the operating time for The remaining heating time is the re- the "Steam bath" mode. maining time when the "Steam bath" mode is turned on. The remaining heat- ing time is reduced automatically. The heating time can be adjusted if the The remaining heating time can be ad- lamp next to the "Steam bath"...
Operation The EN 60335-2-53 "Specific requirements for sauna heating devices" allows the follo- wing maximum heating times: Max. heating time Description more than 12 hours Public cabins which are supervised by trained personnel. max. 12 hours Hotels, apartment blocks, etc. max.
Operation 5.5.1 Adjust the flavour feed The control unit is turned on. Press the (Adjust flavour) key or key till the following view is displayed. Fig. 6: " flavour feed" view (example) Press the key.
Operation Press the key: Reduce value. Press the key: Increase value. 0: slow step 9: quick step Press the key. The adjusted value is accepted. Options menu 5.8.1 Adjust bench temperature – (optional) NOTE! The menu "bench temperature" is only available if this option is avail- able in your device.
Operation Key: Select "auto". – "auto" is enabled. The symbol "auto" (symbol no. 10) appears in the display. Key: Select "manual". Key: without function 11. Press the key. The selection is saved. 12. Exit the menu using the key or select the next line with the key.
Page 27
Option Description FCU4x00 FCU2x00/FCU3x00 If power on Start, as soon as control device is switched on. On heat-up phase Start, as soon as a mode is active. If bath is ready Start, as soon as the set point temperature is reached.
"Basic settings" menu "Basic settings" menu "Basic settings" - general 6.1.1 Time and Weekday In this menu you can set the time and the weekday. Press key (basic settings). The lamp next to the key must light. The weekday appears only, if the weekly timer is released. The following view is shown: ...
"Basic settings" menu 10. Select desired weekday. Check mark flashes. Press -key: move cursor left. Press -key: move cursor right. 11. Press -key. Selection is saved. 12. Leave menu with -key. 6.1.2 Weekly timer ON/OFF (only for FCU4xxx) The timer appears only if the weekly timer is enabled. In this menu you can enable the weekly timer (enable Service menu).
Page 30
"Basic settings" menu - Press the key until you see the following view: Not available with FCU2000 and FCU3000 Fig. 19: "Program the weekly timer" view Press the key. Not available with FCU2000 and ...
"Basic settings" menu 10. Press the key. The selection is saved. 11. Select the next line with the key. 12. You can set the stop time (end) and the duration similar to the start time. If you change the end time, the duration changes automatically. 13.
"Basic settings" menu 6.1.5 Adjust display lighting (not for FCU2xxx) In this menu you adjust the brightness of the display. Press (basic settings) key. The lamp next to the key must light up. Press the key until you see the following view: ...
"Basic settings" menu 6.1.7 Light settings (only for menu "Pro") In this menu you can set the time, when the light should go on and how long it should stay on after the end of a mode. Press (basic settings) key.
"Basic settings" menu Press the key. Check mark is set (option selected). Press the key: Check mark is deleted (option not selected). 12. Press the key. The selection is saved. 13. Exit the menu using the key or select the next line with the key.
Page 35
"Basic settings" menu Fig. 27: "Fan settings – change mode" view (example) Select one of the following lines with the key: – Fan level AUTO (→ point 7) ...
"Basic settings" menu "Basic settings" for options NOTE! These menus appear only if the corresponding options board is avail- able in the control unit. 6.2.1 RGB-LED settings (only for FCU4xxx and menu "Pro") HINWEIS! The "RGB-LED settings" menu is only available for control devices which are connected to a RGB-LED control from the company Licht2000.
"Basic settings" menu Select hand. Cursor flashes on the selected line. Press the key: Increase value. Press the key: Reduce value. There is a maximum time period of 3 seconds possible. Press the key. The selection is saved. Exit the menu using the key or select the next line with the key.
Page 38
"Basic settings" menu Fig. 31: "Colour light automatic – change mode" view (example) Select one of the following lines with the key: – Colour program no. (→...
"Basic settings" menu 17. Press the key. The selection is saved. 18. Exit the menu using the key. 6.2.3 Versions and data (only for menu "Pro") This menu is used for service to, for e.g., quickly find the cause of fault with the versions given here.
Options menu Options menu Small/professional The control unit offers two menu navigations "small" and "professional". The menu "small" includes the main menu items. The menu "professional" includes all menu items. Typically, the menu navigation "small" is sufficient. You can change the menu as follows: Press the key.
Maintenance Maintenance The steam bath controls are maintenance free. Cleaning Aggressive PLEASE NOTE! cleaning agents Device damage possible! Aggressive cleaning agents and additives can damage or destroy the additives electrical components and cable. Therefore: – Do not use cleaning agents and additives with aggressive substan- ces.
General Information 10.2 Copyright Handing over the operating and installation manual to a third party without the written consent of the manufacturer is not permitted. NOTE! The details, texts, drawings, pictures and other representations in this manual are protected by copyright and subjected to the industrial pro- prietary laws.
General Information 10.6 10.7 Safety and instructions Electric DANGER! potential Danger to life due to electric potential! Touching live parts can cause immediate danger to life. Therefore: – Control unit should be opened only by authorised electricians. – Electrical work on the machine should be carried out only by qualified electricians.
General Information If the error cannot be rectified by the end user, please note down the shown display and contact your service technician. Malfunction Possible causes Troubleshooting To be carried out by Service engi- Internal time error Internal time error neer STB circuit open, The connection to the...
Decommissioning and disposal 11 Decommissioning and disposal Do not dispose the sauna control with household waste. Dispose the control unit according to the respective country-specific regulations. 12 Setting value 12.1 Setting value Steam bath min. max. Temperature 35° C 50° C Operating time 00:15 h 06:00 h (20:00 h *)