Digital Equipment DEC 3000 Series Service Information page 333

Front-to-rear cooled systems
Hide thumbs Also See for DEC 3000 Series:
Table of Contents

Advertisement

Run the ISDN diagnostic to verify system operation. If a
3.
failure reoccurs, then replace the FRU listed for that error.
Replace FRUs one at a time, running the ISDN diagnostic
after replacing each one to determine if the failure has been
corrected.
Audio cable
a.
Audio module
b.
I/O boaed
c.
Error Code
Description
02
Data miscompare testing Line Interface Unit Status
register
04
Data miscompare testing Line Interface Unit Priority
register
06
Data miscompare testing Line Interface Unit Mode
register 1
08
Data miscompare testing Line Interface Unit Mode
register 2
A
Data miscompare testing Multiplexer Control
register 1
C
Data miscompare testing Multiplexer Control
register 2
E
Data miscompare testing Multiplexer Control
register 3
10
Data miscompare testing Main Audio Processor
Mode register 1
12
Data miscompare testing Main Audio Processor
Mode register 2
14
Data miscompare testing Data Link Controller Mode
register 1
16
Data miscompare testing Data Link Controller Mode
register 4
20
Data miscompare testing internal digital loopback
using MCR1
24
Data miscompare testing internal digital loopback
using MCR2
26
Data miscompare testing internal digital loopback
using MCR3
28
Data miscompare testing internal analog loopback
30
Interrupt test data miscompare
32
Interrupt test time out
34
Invalid 79C30A interrupt
36
Interrupt not generated
38
All interrupts not received
40
DMA Test time out
42
DMA Test unexpected interrupts
44
DMA Test data miscompare
LED Codes and Status/Error Messages
14–11

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Dec 3000 600s axpDec 3000 400s axpDec 3000 900s axp

Table of Contents