Digital Equipment DEC 3000 Series Service Information page 314

Front-to-rear cooled systems
Hide thumbs Also See for DEC 3000 Series:
Table of Contents

Advertisement

Using the Console and Utilities Commands
13.16.50 RADIX
13.16.51 Format
13.16.52
Example
13.16.53 SCSI_A
13.16.54 Format
13.16.55
Example
13.16.56 SCSI_B
13.16.57 Format
13–42
The RADIX parameter displays the default radix (base number).
The default is hexadecimal.
To execute the SHOW RADIX command, enter the following:
>>> SHOW RADIX
Return
One of the following base address settings appears on the screen:
Base Address
Setting
Description
0
Default base address (hexadecimal)
10
Decimal base address
16
Hexadecimal base address
This example shows that the current radix is set at the default
base address.
>>> SHOW RADIX
Return
Result:
RADIX = 0
>>>
The SCSI_A parameter displays the SCSI ID for the system (A
bus).
To execute the SHOW SCSI_A command, enter the following:
>>> SHOW SCSI_A
Return
A host ID number between 0 and 7 appears on the screen.
This example shows the SCSI A for the system is 6.
>>> SHOW SCSI_A
Return
Result:
SCSI_A = 6
The SCSI_B parameter displays the SCSI ID for the system (B
bus).
To execute the SHOW SCSI_B command, enter the following:
>>> SHOW SCSI_B
Return
A host ID number between 0 and 7 appears on the screen.

Advertisement