13.16.58
Example
13.16.59
SCSI_RESET
13.16.60 Format
13.16.61
Example
13.16.62
SERVER
13.16.63 Format
13.16.64
Example
This example shows the SCSI B for the system is 6.
>>> SHOW SCSI_B
Return
Result:
SCSI_B = 6
>>>
The SCSI_RESET command displays the current time delay
setting.
• A value of 3 is recommended if a floppy and hard disk are
being booted.
• A value of 4 is recommended for tape drives.
• A value of 6 is recommended for CDROM.
To execute the SHOW SCSI_RESET command, enter the
following:
>>> SHOW SCSI_RESET {qualifier}
A number between 0 and 7 appears on the screen.
This example shows that the current value of the SCSI reset is 4.
>>> SHOW SCSI_RESET
Result:
SCSI_RESET = 4
The SERVER parameter shows which server configuration has
been selected.
To display the current configuration, enter the following:
>>> SHOW SERVER
Return
One of the following settings appears on the screen:
Setting
Description
ON
When configuration is a server (Model 400S/600S
or 900S AXP)
OFF
When configuration is a workstation (Model 400
/600 or 900 AXP) (default setting)
This example shows the current SERVER configuration set to
OFF.
>>> SHOW SERVER
Return
Using the Console and Utilities Commands
Return
Return