Digital Equipment DEC 3000 Series Service Information page 309

Front-to-rear cooled systems
Hide thumbs Also See for DEC 3000 Series:
Table of Contents

Advertisement

13.16.24
DIAG_QUICK
13.16.25 Format
13.16.26
Example
13.16.27
DIAG_SECTION
13.16.28 Format
13.16.29
Example
The DIAG_QUICK parameter displays the diagnostic mode.
To execute the SHOW DIAG_QUICK command, enter the
following:
>>> SHOW DIAG_QUICK
One of the following diagnostic settings appears on the screen:
Diagnostic
Setting
Description
ON
Quick verify testing
OFF
Normal testing
This example shows that the diagnostic mode is set to quick verify
testing.
>>> SHOW DIAG_QUICK
Result:
DIAG_QUICK = ON
The DIAG_SECTION parameter determines the diagnostic
environment in which the diagnostics can be run.
To execute the SHOW DIAG_SECTION command, enter the
following:
>>> SHOW DIAG_SECTION
One of the following diagnostic modes appears on the screen:
Setting
Mode
1
Console
2
Service
This example shows that the current diagnostic mode is in console
mode.
>>> SHOW DIAG_SECTION
Using the Console and Utilities Commands
Return
Return
Return
Description
Default mode upon power-on
Provides a more thorough test than
in console mode. Special loopback
connectors may be required to
execute certain tests.
Return
13–37