Tally Dascom DT-210/230
GS ( A pL pH n m
[Function]
Execute test print
[Format]
ASCII
Hex
Decimal
[Range]
(pL + pH × 256) = 2 (pL = 2, pH = 0)
0 ≤ n ≤ 2, 48 ≤ n ≤ 50
1 ≤ m ≤ 3, 49 ≤ m ≤ 51
[Description]
• Executes a specified test print.
• pL, pH specify (pL + pH × 256) as the number of bytes after pH (n and m).
• n specifies the paper used for the test print.
• m specifies a test pattern.
[Note]
• The printer executes software reset after processing this command.
• Clear the receive and print buffers.
• Resets all setting values in RAM (the print area, the character styles, and others) that
were in effect at power on. (The data in the NV memory is not reset.)
GS
(
1D
28
29
40
n
0, 48
Basic sheet (roll paper)
1, 49
2, 50
M
1,49
Hexadecimal dump print
2,50
3,51
A
pL
pH
n
41
pL
pH
n
65
pL
pH
n
Paper source
Roll paper
Test pattern
Printer status print
Rolling pattern print