B. Structure of the EDS files
B.3

Parameter and data in the EDS file

B.3.1 Group SysDiag.Data
SysDiag.Data: Status bits
Function no.
1936
Description
The 8 status bits display common diagnostic messages (global error messages).
Bits 0 ... 3 show the source of the fault and bits 4 ... 7 show the type of the fault.
Bit
Source of fault
Type of fault
Tab. B/5:
Status bits
SysDiag.Data: Diagnostic status
Function no.
1937
Description
The diagnostic status specifies whether there are diagnostic data.
Values
0: There are no diagnostic data
1: There are diagnostic data
Tab. B/6:
Diagnostic status
B−12
With the aid of the function numbers named in the following
tables you can also find information on the relevant data and
parameters of the CPX terminal in the CPX manuals.
00:
Valve
01:
Output
02:
Input
03:
Analogue/function module
04:
Undervoltage
05:
Short circuit/overload
06:
Cable fracture
07:
Other faults
1 = There is a fault
0 = No fault