A. Technical appendix
A.3.11 Object, modification input words function module
Attr.
Access
Description
no.
100
Get/set
Force mode parameter for input word n
101
Get/set
Force state parameter for input word n
1)
Identical with the distribution of the data block of the function input data.
A−22
Object class:
113
Instances:
1 ... 32
The Force, Fail safe and Idle parameters of the inputs of the
function modules are split into words (16 bit) and distributed
among the max. 32 instances of this object. There is no mod
ule orientation. The existing inputs are assigned in blocks of
16 bit in ascending order without gaps.
The first output word of the outputs is administered in in
stance 1. The second output word in instance 2 etc.
Information on the assignment can be found in section A.3.5
and section B.2.2.
Type
1)
WORD
1)
WORD
Festo P.BE−CPX−FB11−EN en 0306a