A. Technical appendix
A.3.5 Assigning the I/O channels with the Force, Fail safe and Idle
parameters
A−16
The Force, Fail safe and Idle parameters for the various chan
nel types are each grouped together in objects.
Object
Description
109
Digital inputs
107
Digital outputs
110
Analogue outputs
111
Analogue inputs
112
Output words function module
113
Input words function module
Tab. A/2:
Objects for the Force, Fail safe and Idle
parameters
The assignment of the channels with the Force, Fail safe and
Idle parameters is identical to the assignment of the para
meters of the EDS file.
The first word receives the lowest instance number of the
relevant object. The second word receives the second lowest
instance number etc.
Further instructions on assigning the Force, Fail safe and Idle
parameters can be found in section B.2.2.
Festo P.BE−CPX−FB11−EN en 0306a