Technical data

General remarks

The cooling capacity of a cooling unit will depend upon:
-
-
-
The flow-rate Q will depend upon:
-
-
FK 6000
Storage temperature
Operating temperature
Mains voltage (auto-transformer)
Mains voltage tolerance
Mains frequency
Fuse (slow-blow)
Mains supply fuse
Coolant pump fuse
Current input
Cooling power (as per IEC 60974-2)
Q = 1 l/min
Q = 1 l/ min
Q = max.
Q = max.
Max. supply rate (Qmax)
Max. pump pressure
Max. supply height
Pump
Flow watchdog switching point
Water filter
Coolant content
Degree of protection
Dimensions L x W x H
Weight (total weight without coolant)
Mains cable
* For factory setting see rating plate
34
NOTE! Inadequately dimensioned electrical installations can lead to serious
damage to (or loss of) property. The mains supply lead, and its fuse protection,
must be dimensioned accordingly. The technical data shown on the rating plate
shall apply.
the ambient temperature
the maximum rise
the flow-rate Q (l/min)
the number of interconnecting hosepacks or connection hoses, and their lengths
the diameter of the hose
+ 25 °C (77 °F)
+ 40 °C (104 °F)
+ 25 °C (77 °F)
+ 40 °C (104 °F)
-25 °C to +55 °C
-13 °F to +131 °F
-10 °C to +40 °C
+14 °F to +104 °F
230 V
+/- 10 %
50 / 60 Hz
3,15 A
1,6 A
1,5 A
1770 W
1120 W
3000 W
2000 W
5 l / min
10.71 cfh
4,2 bar / 60.89 psi
approx. 35 m
114 ft. 10 in.
magnetically-coupled pump
0,8 l / min
0.21 gal / min
100 micrometers, CrNi
screen
9 l / 2.38 gal.
IP 23
725 x 290 x 480 mm
28.54 x 11.42 x 18.90 in.
22 kg / 48.5 Ib.
yes