Mains Connection; Mains Voltage Of Fk 6000; Setting The Mains Voltage Of Fk 6000 Pipe - Fronius FK 6000 Operating Instructions And Spare Parts List

Cooling unit
Table of Contents

Advertisement

Mains connection

The equipment is designed to run on the mains voltage given on the respective rating
plates. If your version of the appliance does not come with the mains cables and plugs
ready-mounted, these must be mounted in accordance with your national regulations and
Standards. For details of fuse protection of the mains supply lead, please see the Techni-
cal Data.
Mains voltage of
FK 6000
FK 6000: fixed mains voltage
Setting the mains
The FK 6000 Pipe cooling unit can be used with different mains voltages. The mains volt-
voltage of FK
age set at the factory is shown on the rating plate.
6000 Pipe
FK 6000 Pipe: Setting the mains voltage
26
NOTE! Inadequately dimensioned electrical installations can lead to serious
damage to (or loss of) property. The mains supply lead, and its fuse protection,
must be dimensioned accordingly. The technical data shown on the rating plate
shall apply.
CAUTION! Running the unit on the wrong mains voltage can cause serious dam-
age. The mains voltage that you enter on the rating plate must be the same as
the voltage that you have just set.
IMPORTANT! The FK 6000 cooling unit is
fixed at 230 V. It cannot be altered to any
other mains voltage.
How to set the mains voltage:
Shift the mains switch into the "O" po-
1
sition
Unplug or otherwise disconnect the
2
unit from the mains power supply
Open the housing
3
Connect the phase conductor (L1) to
4
the appropriate terminal for your mains
voltage
Check that all cables are fixed firmly
5
Close the housing
6
Cross out the mains voltage originally
7
entered on the rating plate and - in the
empty box - enter the mains voltage
that you have just set