FK 6000 Pipe

Storage temperature
Operating temperature
Mains voltage (auto-transformer)
Mains voltage tolerance
Mains frequency
Fuse protection (slow-blow)
Fuse for mains power supply
Fuse for coolant pump
Power consumption
Cooling capacity (to IEC 60974-2)
Q = 1 l/min
Q = 1 l/ min
Q = max.
Q = max.
Max. delivery rate (Qmax)
Max. pump pressure
Maximum rise
Pump
Switching point of rate-of-flow watchdog (Option)
Water filter
Coolant volume
Degree of protection
Dimensions L x W x H
Weight (overall weight without coolant)
Mains cable
* see rating plate for factory setting
+ 25 °C (77 °F)
+ 40 °C (104 °F)
+ 25 °C (77 °F)
+ 40 °C (104 °F)
-50 °C to +55 °C
-58 °F to +131 °F
-25 °C to +40 °C
-13 °F to +104 °F
110* / 230 V
+/- 10 %
50 / 60 Hz
3,15 A
1,6 A
1,5 - 3,9 A
1770 W
1120 W
3000 W
2000 W
5 l / min
10.71 cfh
4,2 bar
60.89 psi
approx. 35 m
114 ft. 10 in.
magnetically-coupled pump
0,8 l / min
0.21 gal / min
100 micrometre, CrNi sieve
9 l
2.38 gal.
IP 23
725 x 290 x 480 mm
28.54 x 11.42 x 18.90 in.
24 kg
52.91 Ib.
no