Setting the mains
voltage of FK
6000 - 400 V
FK 6000 - 400 V: Setting the mains voltage
How to set the mains voltage
Shift the mains switch into the "O" po-
1
sition
Unplug or otherwise disconnect the
2
unit from the mains power supply
Open the housing
3
Connect the phase conductor (L1) to
4
the appropriate terminal for your mains
voltage
Check that all cables are fixed firmly
5
Close the housing
6
Cross out the mains voltage originally
7
entered on the rating plate and - in the
empty box - enter the mains voltage
that you have just set.
27