Water Inlet Solenoid; Power Supply (24Vdc) - Cornelius Nitropro Mini Service And Preventative Maintenance Manual

Specialty beverage dispenser
Table of Contents

Advertisement

6.6 W
I
S
ATER
NLET
OLENOID
Figure 6‐8 ‐ Water Inlet Solenoid & Mounting
1) Shut off the water supply to the unit and then dispense a
still coffee (left tap handle) drink to relief any water pres‐
sure in the lines.
2) Shut off power to the dispenser and unplug the power
cord from the wall receptacle.
3) Remove the enclosure top panel and then the right‐side
and rear access panels from the dispenser.
4) Disconnect the water‐supply hose from the inlet sole‐
noid.
5) Remove the two back‐panel, Phillips screws securing the
inlet solenoid bracket.
6) Partially remove the inlet solenoid and then remove the
dispenser water‐inlet hose from it.
7) Connect the dispenser water hose to the replacement
solenoid.
8) Reinstall the solenoid in reverse order.
© 2019, Cornelius Inc. All Rights Reserved
6.7 P
S
OWER
UPPLY
1) Shut off power to the dispenser and unplug the power
cord from the wall receptacle.
2) Remove the enclosure top panel and then the right‐side
access panel from the dispenser.
3) Disconnect the AC wiring from the top of the power sup‐
ply (Fig. 6‐9).
4) Remove the screws securing the power supply to the
enclosure rail.
5) Remove the power supply partially from the enclosure
and disconnect the DC wiring from the bottom terminals.
Then remove it entirely.
6) Install the new power supply in reverse order.
Figure 6‐9 ‐ 24Vdc Power Supply & Mounting
‐ 29 ‐