PREVENTATIVE MAINTENANCE

!
WARNING:
Shutdown unit via the proper software shutdown procedure. When the computer has fully turned off, unplug the unit
from the wall outlet.
Failure to comply could result in serious injury, death or damage to the equipment.
!
CAUTION:
Do not use metal scrapers, sharp objects or abrasives on the ice storage hopper, top cover or exterior surfaces, as
damage to the unit may result. Do not use solvents or other cleaning agents as they may attack the material
resulting in damage to the unit.
• Soap solution – Use a mixture of mild detergent and warm (100° F) potable water.
• Sanitizing Solution – Dissolve 1 packet [1 oz. (29.6 ml)] of Stera Sheen Green Label (or KAY-5 Sanitizer/
Cleaner) into 2-1/2 gallons (3.79 l) of warm [80-100° F (26.7-37.8° C)] potable water to ensure 100 ppm of
chlorine.
C
PBD175 (S
LEANING THE

Daily Cleaning

!
WARNING:
Do not use abrasive cleansers.
Remove the cup pedestal from the ice slide, as shown in Figure 12, and clean them with warm soapy water, rinse
them with clean water and allow them to air dry.
Wipe down the display screen and the exterior of the unit with warm soapy water. Then rinse with clean water and
wipe with a clean soft cloth.
Remove the nozzle and separate it components, as shown in Figure 13 and Figure 14. Wash them in warm soapy
water, rinse in clean warm water and allow to air dry.
Wipe down the bottom of the dispensing valve with a clean damp cloth.
© 2015-2016, Cornelius Inc.
3.0)
PIRE
Figure 12.
- 11 -
PBD175 (Spire 3.0)) Service Manual
Cup pedestal
Ice Slide
Publication Number: 620062609SER