Preventative Maintenance; Summary - Cornelius FRUITISTA 3 Service Manual

Fruitista viper 3 flavor
Table of Contents

Advertisement

PREVENTATIVE MAINTENANCE

S
UMMARY
© 2010-2011, IMI Cornelius Inc.
There are no daily maintenance procedures required on the Viper unit other than
normal cleanup of spills or overspray and emptying the drip tray. Normal equip-
ment maintenance intervals are listed in Table 33. It is recommended that a pre-
ventative maintenance procedure be performed every six (6) months. This
procedure should include all of the maintenance items described in Table 33 and
the following sections.
Preventative Maintenance Summary
Maintenance Procedure
Clean Air Filter
Check BRIX
Seal Change
Clean Condenser Coil
Sanitize Unit
Change or Rotate Scraper Blades
Check for Leaks
Clean BIB Connectors & check opera-
tion of syrup sold out switches
Check Clock Setting
Change caged o-ring on models w/
Motorman Valves.
!
CAUTION:
Only trained and certified electrical, plumbing and refrigeration technicians
should service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO
NATIONAL AND LOCAL CODES.
- 41 -
Viper Service Manual
Table 33.
Frequency of Maintenance
Monthly or more often, as necessary (See
Table 34)
Every six months or when changing syrup
types (See "BRIX Setup Menu" on page 31.)
Every six months
Every six months or as necessary
Every six months or when changing syrup
types
Every six months
Every six months
Every six months or when changing syrup
types.
Every six months or when changing to or
from daylight savings time
Every six months or when changing syrup
types.
Publication Number: 621360041TBSER