Nitropro Mini Service Manual
Figure 6‐14 ‐ Agitator Wiring Socket on Controller Module
5) Loosen the thumbscrew at the base of the agitator motor
(Fig. 6‐13).
6) Lift and angle the motor assembly to withdraw it from the
ice bank.
7) Install the replacement motor in reverse order.
Figure 6‐15 ‐ Agitator Pump Hose Orientations
Publication Number: 548000106SER

6.9.3 Ice Bank Controller

1) Shut off power to the dispenser and unplug the power
cord from the wall receptacle.
2) Remove the enclosure top panel and then the left‐side
access panel.
3) Remove the drip tray, splash panel and the Main PCB
housing (refer to section 6.3).
4) Unplug the four wiring connectors from the ice bank con‐
troller module (Fig. 6‐16).
Figure 6‐16 ‐ Ice Bank Controller Module Removal
5) Slide the controller to the right, off its mounting and
remove the controller.
6) Install the replacement controller in the reverse manner.