Summary of Contents for Cornelius In-N-Out Burger NGF 255
Page 1
IN-N-OUT BURGERS NGF 255 WITH COLD CARBONATION Installation Manual Release Date: January 27, 2011 Publication Number: 621058476INS Revision Date: N/A Revision: A Visit the IMI Cornelius web site at www.cornelius.com for all your Literature needs.
Commercial Warranty. Cornelius will not be responsible for any repair, replacement or other service required by or loss or damage resulting from any of the following occurrences, including but not limited to, (1) other than normal and proper use and normal...
In-N-Out Burger NGF 255 Installation Manual DESCRIPTION The NGF 255 dispenser solves your ice and beverage service needs in a sanitary, space saving, economical way. Designed to be manually filled with ice from any remote ice-making source, this dispenser dispenses cubes (up to 1- 1/4 inch in size), cubelets and compressed (not flaked).
“traps” or improper drainage will result. NOTE: IMI Cornelius Inc. recommends that a water shutoff valve and water filter be installed in the plain water inlet supply line. A Cornelius Water Filter (P/N 313860000) and QUICK DISCONNECT SET (P/N 313867000) are recommended.
In-N-Out Burger NGF 255 Installation Manual outlet to Ice/Drink Unit using 3/8-inch food-grade tubing. Disable the pump from operating by switching the switch in the carbonator pump assembly junction box to the OFF position. 6. Connect the beverage system product tubes as indicated in the Flow Diagram, Figure 4 This work should be done by a qualified service person.
Page 10
In-N-Out Burger NGF 255 Installation Manual restrictor plate can now be moved up or down. When the restrictor plate is fully up, the ice gate opening is 2-1/2” in height, and the maximum rate of ice dispense is available (approximately 3 oz/sec). Retighten the (4) nuts to set the desired restrictor plate opening.
In-N-Out Burger NGF 255 Installation Manual TROUBLESHOOTING IMPORTANT: Only qualified personnel should service internal components or electrical wiring. WARNING: If repairs are to be made to a product system, remove quick disconnects from the applicable product tank, then relieve the system pressure before proceeding. If repairs are to be made to the CO system, stop dispensing, shut off the supply, then relieve the system pressure before proceeding.
Page 17
In-N-Out Burger NGF 255 Installation Manual Check electrical connection to water valve. Check resistance of coil (should be 9 ohms). Water valve will not open Check for voltage at coil when brand button is depressed. Carbonator tank is empty, because tank was Unit will not dispense car- Unplug the unit and reconnect the unit.
In-N-Out Burger NGF 255 Installation Manual IAGNOSTICS UIDE FOR THE ONTROL OARD Observed State of State Sensor Input Control Response Service Remedy Red LED Flash rate 3 sec- Standby mode. Pump = Both probes read “wet” No service required onds...