Functions
All devices have the following functions:
● Configuration with the Primary Setup Tool (PST) V3 or higher;
to use the Primary Setup Tool to assign the IP address, the switches must be accessible
via Ethernet.
● Configuration of the IP address with DHCP
● Configuration with STEP 7 V 5.3 plus SP 1
● Web Based Management
● Command Line Interface
● Configuration with STEP 7
● SNMP
● SNTP
● PROFINET diagnostics
● Topology support (LLDP)
● Ring redundancy including RM functionality
● Passive listening
● Standby redundancy
● IRT capability
● Fast learning
4.5.11.3

Interfaces

Device
X200-4P IRT
X201-3P IRT
X201-3P IRT PRO
X202-2IRT
X202-2P IRT
X202-2P IRT PRO
X204IRT
X204 IRT PRO
* With a cable cross-section of 50 µm
** With a cable-cross section of 62.5 µm
*** For POF fiber-optic cables 1 - 50 m and PCF fiber-optic cables 1 - 100 m
Industrial Ethernet
System Manual, 09/2019, C79000-G8976-C242-10
Twisted pair
10/100 Mbps
-
1x RJ45
1x RJ45
2x RJ45
2x RJ45
2x IE RJ45 Plug PRO
4x RJ45
4x IE RJ45 Plug PRO
SCALANCE network components
4.5 SCALANCE X Industrial Ethernet Switches
Fiber-optic cables
100 Mbps
4x SC RJ/ push-pull plug,
POF/PCF
3x SC RJ/ push-pull plug,
POF/PCF
3x SC-RJ/ push-pull plug
PRO, POF/PCF, multimode
2x ST/BFOC, multimode
2x SC RJ, POF, multimode
2x SC RJ/ push-pull plug
POF/PCF, multimode
-
-
Max. segment length / km
0.05 / 0.100 ***
0.05 / 0.100 ***
0.05 / 0.100 ***
4* / 5**
0.05 / 0.100 ***
0.05 / 0.100 ***
-
-