Article numbers
Component
CP 1616
7.3
CP 1623
Description
Figure 7-4
The CP 1623 is a PCI Express card with its own microprocessor and integrated 2-port switch
for connecting PCs and SIMATIC PGs/PCs to Industrial Ethernet. PNIO is not supported by
this module.
Features
Required slot on the PC
Number and type of the interfaces for Industrial Ethernet
Gigabit Ethernet
Own microprocessor
Optional external power supply 12 ... 24 VDC
Functions
● Up to 120 connections can be configured at one time
● Transmission rates 10/100/1000 Mbit/s (half/full duplex)
Industrial Ethernet
System Manual, 09/2019, C79000-G8976-C242-10
Description
PCI-104 card (32-bit; 3.3 / 5 V universal keyed) with ASIC
ERTEC 400 for connecting PCs to PROFINET IO with 4-port
real-time switch (RJ45); including IO-Base software for
PROFINET IO controller and NCM PC
CP 1623
Communications processors for PCs
Article number
6GK1161-6AA02
CP 1623
PCI Express x1
2x RJ45
7.3 CP 1623
303