Mounting and connection
4.5 Wiring the carrier controller
Procedure
Note
Components may only be installed or removed while the power supply is shut down. When
working in and on electrical systems, you should always observe the specifications in the
section "Safety instructions (Page 15)".
1. Connect the connector to the appropriate cable.
The connector pin assignment is specified in the section "Interface description (Page 44)"
2. If sensors are used, connect the associated sensor.
Take care not to damage the connectors when terminating the cables.
4.5.3
Interfaces
①
②
③
④
⑤
⑥
⑦
22
Brake resistor interface
Power supply and data transmission interface
PROFINET interface
Interface for the geared motor that drives the EMS carrier
Interfaces for on sensor each
Interface of an analog sensor
PE bolts –EP01
Operating Instructions, 09/2013, A5E03474162-02