Setting up the TSSC for use with the TS7650G

TSSC Not Installed. Proceed. . .
This will install the Console onto /dev/sda which will erase everything on that device
Continue? ('yes' or 'no')
Abort
8. Type y and press Enter. The hard drive rebuild process begins.
9. When the rebuild is complete, the TSSC restarts automatically. Remove the
CD-ROM from the CD drive.
Note: This procedure can take as long as 15 minutes to complete. You must
be present at the completion of the restart or the code load will restart
automatically. If you are not present to remove the CD-ROM from the CD
drive tray, the tray will retract into the CD drive and the installation will start
again.
10. At the console install confirmation prompt, type n and press Enter.
11. Remove the CD-ROM from the CD drive. The system will automatically
restart.
After the initial restart, the software will determine the machine type and
model number of the computer, automatically configure the appropriate
drivers and settings, and automatically restart the TSSC. During the second
restart, the startup background and text may look slightly different. The login
menu will be displayed following the second restart. If the software
determines that the machine type is not 6579, 6792, 8480, 8482, 8485, 8836, or
8849, a warning message will display on the screen and the TSSC will halt.
This will continue each time the TSSC is powered on. Similar symptoms occur
after software installation if the TSSC is unable to determine its machine type
and model.
Note: If a product with a machine type of 6579, 6792, 8480, 8482, 8485, 8836,
or 8849 reports a different machine type during an installation, the BIOS may
have been corrupted. Restart the server, and make the appropriate selection
during the restart to enter BIOS setup. In the BIOS, check the machine type
that is configured. If the machine type does not match the specific server, you
should reinstall the system BIOS. Refer to the server documentation to
reinstall the BIOS and to set the correct machine type.
12. Restore the TSSC's configuration from the backup. Refer to the IBM System
Storage TS3000 System Console (TSSC) Maintenance Information for instructions.
Before the TSSC can be used to support the gateway, you must first configure the
TSSC's Call Home, firewall, and network communications settings.
Procedure
1. If the TSSC is not already powered-on, do so now.
Note: When powering on the TS3000 TSSC several hardware checks run
automatically. During these checks failure indications are displayed for the
Eclipse Framework and AOTM. These failure indications can be ignored as
they are normal and do not interfere with the operation of the TSSC or its
communication to the ProtecTIER server. Failure indications other than those
noted require attention. Identify any failing routines and if needed, contact
your next level of support.
2. If prompted for login information, enter the username: service and the
password: service.
The TSSC's blue desktop displays. See Figure 31 on page 78.
Chapter 5. Setting up the TSSC for use with theTS7650G server
77